Abstract
The application of transcatheter aortic valve implantation (TAVI) in a wider and younger
population in the near future makes the need to successfully deal with challenging
procedural conditions an imperative. We report a case in which TAVI was successfully
conducted in a patient with aortic coarctation using a last-generation low-profile
bioprosthesis. Despite the fragile aortic wall and its possible abnormal function,
a low-profile (14F) CoreValve Evolute R device (Medtronic, Minneapolis, MN) was implanted
through the coarctation without complications. Last-generation, low-profile transcatheter
implanted aortic valves provide an additional advantage in patients with structural
impediments.
Résumé
L’implantation valvulaire aortique par cathéter (IVAC) chez un plus grand nombre de
patients et chez des patients plus jeunes se fera de plus en plus courante. C’est
pourquoi il est impératif d’arriver à pratiquer cette intervention même dans des conditions
difficiles. Nous présentons un cas où une IVAC a été réalisée avec succès chez un
patient qui présentait une coarctation de l’aorte. En dépit d’une paroi aortique fragile
et dont le fonctionnement était possiblement compromis, l’équipe a été en mesure d’implanter
une bioprothèse faiblement profilée (low-profile) de toute dernière génération, soit un dispositif CoreValve Evolute R (14F) (Medtronic,
Minneapolis, Minnesota) en passant par la coarctation sans que cela n’entraîne de
complications. L’implantation de ces nouvelles valves aortiques offre un avantage
additionnel chez les patients qui présentent des problématiques structurelles.
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Canadian Journal of CardiologyAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Transcatheter aortic valve implantation: current and evolving indications.Can J Cardiol. 2011; 32: 266-269
- Coarctation of the aorta.Circulation. 2015; 131: e363-e365
Article info
Publication history
Published online: January 25, 2016
Accepted:
January 18,
2016
Received:
November 22,
2015
Footnotes
See page 1575.e7 for disclosure information.
Identification
Copyright
© 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.