Multiple Thromboembolic Events from a Left Atrial Appendage Occlusion Device

Published:December 26, 2017DOI:https://doi.org/10.1016/j.cjca.2017.12.017

      Abstract

      Left atrial appendage occlusion devices are an alternative to oral anticoagulation in patients with nonvalvular atrial fibrillation who are at risk of ischemic stroke. Thromboprophylaxis after implantation is recommended, but the optimal regimen is unknown. We report a clinicopathologic case in which thrombus adherent to an incompletely endothelialized WATCHMAN device (Boston Scientific, Marlborough, MA) resulted in multiple thromboembolic events, contributing to a fatal outcome. This case illustrates uncertainties regarding the device's endothelialization process.

      Résumé

      Les dispositifs d’occlusion de l’appendice auriculaire gauche sont une alternative à l’anticoagulation par voie orale chez les patients atteints de fibrillation auriculaire non valvulaire qui sont exposés au risque d’accident vasculaire cérébral ischémique. On recommande la thromboprophylaxie après l’implantation, mais on ignore le schéma posologique optimal. Nous décrivons les caractéristiques clinicopathologiques d’un cas chez qui le thrombus adhérent au dispositif WATCHMAN non totalement endothélialisé (Boston Scientific, Marlborough, MA) a entraîné de multiples événements thrombo-emboliques qui ont contribué à l’issue fatale. Ce cas met en lumière les incertitudes concernant le processus d’endothélialisation du dispositif.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Canadian Journal of Cardiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Reddy V.Y.
        • Möbius-Winkler S.
        • Miller M.A.
        • et al.
        Left atrial appendage closure with the Watchman device in patients with a contraindication for oral anticoagulation: The ASAP study (ASA Plavix Feasibility Study With Watchman Left Atrial Appendage Closure Technology).
        J Am Coll Cardiol. 2013; 61: 2551-2556
        • Reddy V.Y.
        • Holmes D.
        • Doshi S.K.
        • Neuzil P.
        • Kar S.
        Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry.
        Circulation. 2011; 123: 417-424
        • Saw J.
        • Fahmy P.
        • Azzalini L.
        • et al.
        Early Canadian multicenter experience with WATCHMAN for percutaneous left atrial appendage closure.
        J Cardiovasc Electrophysiol. 2017; 28: 396-401