      Transcatheter pulmonary valve (TPV) replacement is an effective therapy of right ventricular outflow tract conduit dysfunction. Acute complications after TPV implantation include infective endocarditis, stent fracture, and device dislocation. We present a novel, life-threatening complication: an acute, noninfectious TPV thrombosis. Within 24 hours after implantation of a Melody system (Medtronic, Inc, Minneapolis, MN), the patient developed an acute TPV thrombosis characterized by severe TPV stenosis on echocardiography and contrast filling defects on computed tomography pulmonary angiography images. Genetic testing revealed heterozygous prothrombin G20210A polymorphism and homozygous 4G/4G polymorphism of the plasminogen-activator-inhibitor. The patient recovered after surgical valve replacement with a pulmonary homograft.

      Résumé

      Le remplacement de la valve pulmonaire par cathéter (VPC) est un traitement efficace contre la dysfonction de la chambre de chasse du ventricule droit. Les complications à court terme après l’implantation de la VPC sont les suivantes : l’endocardite infectieuse, la fracture de l’endoprothèse et la dislocation du dispositif. Nous présentons une nouvelle complication mettant en danger la vie du patient, soit la thrombose non infectieuse de la VPC. Dans les 24 heures qui suivent l’implantation d’un dispositif Melody (Medtronic inc., Minneapolis, MN), le patient a subi une thrombose aiguë de la VPC caractérisée par une sténose grave de la VPC selon les images de l’échocardiographie et des défauts de remplissage du produit de contraste selon les images de l’angiographie pulmonaire par tomodensitométrie. Le dépistage génétique a révélé un polymorphisme G20210A de la prothrombine à l’état hétérozygote et un polymorphisme 4G/4G à l’état homozygote de l’inhibiteur des activateurs du plasminogène. Le patient s’est rétabli après la chirurgie de remplacement valvulaire par homogreffe pulmonaire.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Canadian Journal of Cardiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Verhoeven P.A.
        • Learn C.P.
        • Brown N.M.
        • Goldstein B.H.
        Noninfective transcatheter pulmonary valve thrombosis: a rare cause of post-implantation pulmonary valve obstruction.
        JACC Cardiovasc Interv. 2017; 10: e119-e122
        • Schneider A.E.
        • Delaney J.W.
        • Cabalka A.K.
        Non-infectious thrombosis of the Melody® valve: a tale of two cities.
        Catheter Cardiovasc Interv. 2016; 88: 600-604

      Linked Article

      • Erratum
        Canadian Journal of CardiologyVol. 35Issue 6
        • Preview
          In the article, “First Report of an Acute, Obstructive Thrombosis of a Melody Valve Used for Transcatheter Pulmonary Replacement” by Kellermair et al., published in the December 2018 issue (Can J Cardiol 2018;34:1688.e13-15), the authors’ first and last names were transposed for all but the first author. The author list should be corrected as follows:
        • Full-Text
        • PDF